Guide

Try-in and cementation by material

General seating and cementation guidelines by material.

For: the dentist and assistant seating the restoration.

These are general guidelines. Always follow the instructions of the cement and primer manufacturers.

Our zirconia and e.max are Ivoclar materials, so Ivoclar's own protocols apply directly. The Ivoclar Cementation Navigation System is a free tool that recommends a cement for the restoration and the tooth or abutment, and shows each step.

Try-in

  • Check proximal contacts first, then marginal fit, then occlusion.
  • Evaluate the shade with a try-in paste or water before cementation, particularly for e.max and veneers.
  • After try-in, clean the intaglio surface. Saliva contaminates zirconia and reduces bond strength; use a cleaning agent made for the purpose or air abrasion, not phosphoric acid.

Zirconia (IPS e.max Zirconia)

Ivoclar indicates three cementation methods for IPS e.max Zirconia crowns and bridges. After try-in, clean the bonding surface with Ivoclean.

MethodRestoration surfaceIvoclar luting materialPreparation
ConventionalClean with IvocleanZirCAD CementRetentive: 4 to 8 degrees, at least 4 mm high
Self-adhesiveClean with IvocleanSpeedCEM PlusRetentive: 4 to 8 degrees, at least 4 mm high
AdhesiveClean with Ivoclean, then Monobond PlusVariolink Esthetic DCRetentive form not required

Zirconia veneers, inlays, onlays, cantilever bridges and resin-bonded bridges are indicated by Ivoclar for adhesive cementation only (Variolink Esthetic; the light-cured version only where the material is under 1.5 mm thick).

Lithium disilicate (IPS e.max)

  • Adhesive cementation is required for veneers, inlays, onlays and crowns prepared to the reduced 1.0 mm thickness. Ivoclar's protocol uses Monobond Etch & Prime on the restoration, Adhese Universal on the tooth and Variolink Esthetic.
  • Crowns and partial crowns with conventional reduction (1.5 mm) may also be cemented self-adhesively or conventionally, according to Ivoclar.
  • Etch and prime the restoration after try-in and cleaning, immediately before seating.

PFM and full metal

  • Our PFM porcelain is Ivoclar IPS Style. It is seated like any PFM restoration.
  • Conventional or resin-modified glass ionomer cement. No surface treatment is required.

Screw-retained implant restorations

  • Confirm complete seating with a radiograph before final torque.
  • Torque the screw to the implant manufacturer's specification.
  • Protect the screw head, then seal the access channel with composite.

If a restoration does not fit

Call 484-891-1071 before adjusting extensively. A photograph, or a new scan with the restoration seated, helps us identify the cause.

Manufacturer references

Values marked "Ivoclar" on this page are taken from Ivoclar's published documentation. Refer to the current documents for complete instructions.

Request information

Complete the form and a member of our team will respond within one business day.

Or call 484-891-1071.

TDB Dental Lab
301 S. Main St, STE 2S
Doylestown, PA 18901
Monday to Thursday, 9am to 5pm

Provide a phone number or an email address. It is used only to respond to this request.

A member of our team will respond within one business day. To speak with us now, call 484-891-1071.